NiT-Vu™ High-Performance Micro Guidewire

Have Visibility, Have Control

NiT-Vu Offering:
  • The NiT-Vu is available in straight or angled tip to meet specific procedural and anatomical needs
  • The NiT-Vu is available in 2 cm, 5 cm or 7 cm tip length, giving the clinician a variety of choices based on the case’s specific needs
  • Available in 0.014” and 0.018”
  • Available in 80 cm, 110 cm, 180 cm and 300 cm lengths

Features:
  • Kink-resistant Ni-Ti alloy core wire assures smooth, kink-free navigation through tortuous vasculature and accurate wire control; allows for a 1:1 torque response at the distal tip
  • Highly radiopaque tungsten coil tip for excellent visibility under fluoroscopy
  • Wire’s inner core features a smooth, parabolic tip taper to facilitate efficient, atraumatic placement through tortuous anatomy
  • Advanced formulation silicone coating technology produces lubricity between the wire surface and the vessel wall, providing smooth navigation
     

AQUALiner® Hydrophilic Ni-Ti Alloy Guidewire*

Next-Generation Hydrophilic Performance

The real test of effective hydrophilic performance is endurance, and if a guidewire’s lubricity diminishes over the course of a procedure the result can be time-consuming and costly. The AQUALiner guidewire with a hydrophilic coating from AngioDynamics is engineered to last as long as the procedure does, providing the hydrophilic longevity that minimally-invasive procedures demand.

AQUALiner also provides exceptional kink-resistance and a softer, smoothly tapered chemically engineered tip, which combine to assure efficient, atraumatic interventional procedures even in the most tortuous anatomy. Laboratory testing applied a constant load to coating surface while guidewire was moved up and down, with results demonstrating better adhesion endurance of AQUALiner’s coating vs. the leading competitor. With the additional a choice of straight or angled tip, AQUALiner provides the right configuration for any clinical need.

Features:
  • AQUALiner’s advanced coating technology produces a “cushion” of moisture between the wire surface and either vessel walls or instrumentation, promoting smooth, frictionless navigation
  • A Ni-Ti alloy core, plus the right blend of suppleness and rigidity, assure smooth, kink-free navigation through even the most tortuous vasculature


PTFE Coated Guidewire*

A variety of designs to meet a diversity of needs

Fixed Core Features:
  • Tight specifications provide accurate measurements for improved catheter tracking
  • Uniform coating of PTFE provides lubricity and a smooth outer surface for easy insertion
  • Unique process provides tighter coils, minimizing possible thrombus buildup
     
Movable Core Features:
  • PTFE coating on inner mandril facilitates consistent core movement
  • Flat-wound construction provides smooth insertion of core wire, facilitating the clinician’s overall guidewire placement
  • Round safety wire facilitates advancement or withdrawal of core wire

*The AQUALiner Hydrophilic Ni-Ti Alloy Guidewire
and PTFE Coated Guidewires do not have a CE Mark.